This temperature was arrived at by running a flow test and determining that the DHW coil in the solar tank will deliver 120 F water continuously when the tank temperature is 125 F.Also the space heating coils will deliver essentially 125 F water to the input of the boiler. Since this is above the normal temperature required for supply to the floor, there is no need for the boiler to run. Both sets of coils in the solar tank can be shut off with ball valves, if need be, and then the boiler will provide DHW and space heating.The input and output of both sets of coils and the supply and return of the radiant floor have inline thermometers to provide information on system operation. There are four
SunEarth Empire EC-32 collectors, attached to the south wall of our log home, that have water pumped through them by a three speed
Grundfos Alpha pump. I have the pump set to operate at the middle speed. The pump is controlled by a Solar Thermal differential controller that senses the water temperature at the top and bottom of the tank and also the temperature of the air inside the collectors. The controller is set to allow a maximum temperature of 140 F inside the tank. If the tank temperature is below 140, the controller is further set to start the pump any time the collector temperature is more that 16 degrees above the bottom water temperature. The controller turns the pump off if the collector temperature falls to within 8 degrees of the tank water temperature. At this point all the water in the collectors drains back to the tank. The controller has a safety feature which prevents starting the pump if the collector temperature is above a preset upper limit to prevent steam generation. The circulation piping has a Pentair flowmeter which shows water flow rate while the pump is running and acts a sight glass for tank water level when the pump is idle.